Description
C&G Pull Switch: Convenient and Compliant Control
The C&G Pull Switch is specifically designed for installation in environments where moisture may be present, such as bathrooms and shower rooms. By being mounted on the ceiling or high on the wall, and operated via a non-conductive cord, it meets stringent electrical safety requirements for use in these zones. The simple 1‑gang, 1‑way configuration provides straightforward on/off control of a single lighting circuit, making it an ideal replacement or new fit for toilets, utility rooms, and bathrooms.
C&G Pull Switch: Key Specifications
| Specification | Details |
|---|---|
| Product Type | Ceiling Pull Cord Switch |
| Gang Size | 1 Gang |
| Way Configuration | 1 Way |
| Current Rating | 6 AX |
| Voltage | 230V AC |
| Switch Action | Double pole (disconnects both live and neutral) |
| Terminal Capacity | Accepts up to 3 x 4.0mm², 2 x 6.0mm², or 1 x 10.0mm² cables |
| Mounting | Ceiling / Surface mount |
| Material | High-quality Urea (front plate) , Thermoplastic (base) |
| Colour | White |
| Dimensions (H x W) | 86mm x 86mm (standard faceplate size) |
| Fixing Centres | 60.3mm |
| Min. Back Box Depth | 45mm (for double pole switches) |
| IP Rating | IP20 (indoor use only) |
| Standards | BS EN 60669-1 |
| Features | Robust cord, halogen-free materials available , screw terminals |
| Applications | Bathrooms, shower rooms, toilets, utility rooms, kitchens |
C&G Pull Switch: Double Pole Safety
A key safety feature of this pull switch is its double pole action. Unlike a standard single pole switch which only disconnects the live conductor, a double pole switch disconnects both the live and neutral conductors when turned off. This ensures the complete isolation of the connected light fitting, providing an extra level of safety, particularly important in potentially damp environments .
C&G Pull Switch: Design and Construction
The C&G Pull Switch is built for durability and a consistent appearance. The front plate is typically manufactured from high-quality Urea, prized for its excellent insulation properties, durability, and resistance to scratching and discolouration over time . The smooth white finish is easy to wipe clean and resists yellowing, ensuring it remains looking good for years. Internally, the switch features robust screw terminals with generous capacity, capable of accommodating a wide range of cable sizes for easy installation .
C&G Pull Switch: Applications
This versatile pull switch is specifically suited for applications where safety and convenience are key:
Bathrooms and Shower Rooms: Mounted out of reach of water sources, the cord allows safe operation of lights in accordance with IP-zone regulations.
Toilets and Utility Rooms: Offers a convenient, easy-to-reach control, especially useful for children or those with limited mobility.
Kitchens: Can be used for under-cabinet or island lighting, providing a switch location away from the main splash areas.
Cellars and Lofts: Ideal for lighting in spaces where a wall switch is impractical or where the switch needs to be located near the entrance.
C&G Pull Switch: Installation
Installation should be carried out by a qualified electrician in accordance with current wiring regulations (BS 7671 in the UK):
Isolate Power: Ensure the circuit is isolated at the consumer unit before commencing any work.
Prepare the Box: This switch is designed for surface mounting directly onto a ceiling or wall, or can be mounted on a suitable flush or surface pattress box. A minimum back box depth of 45mm is recommended to accommodate the double pole mechanism .
Connect Wires: Connect the live (brown) and neutral (blue) conductors to the appropriate terminals. Earth conductors must be connected to the earth terminal .
Secure Terminals: Tighten all terminal screws firmly, ensuring no stray strands are exposed. The generous terminal capacity accepts up to 10.0mm² cable .
Secure the Switch: Offer the switch up to the mounting surface or back box, aligning the fixing holes. Insert the mounting screws and tighten gently until the switch sits flush.
Final Check: Ensure the switch is secure and sits neatly against the surface.
Test: Restore power and test switch operation using the pull cord.
C&G Pull Switch: Important Notes
This switch disconnects both live and neutral conductors when in the OFF position, providing complete circuit isolation .
Suitable for indoor use only (IP20 rating) .
All wiring must comply with current wiring regulations.
If the switch shows signs of damage, replace immediately.
Clean with a soft, damp cloth only. Do not use abrasive cleaners.
C&G Pull Switch: Quality Assurance
The C&G Pull Switch is manufactured to meet relevant British and international safety standards, including BS EN 60669-1, ensuring rigorous testing for electrical safety and performance . When correctly installed, this reliable and compliant switch provides years of dependable service, offering safe and convenient lighting control in the most suitable locations.